CORROSION TESTS AT THE WATER TREATMENT PLANT IN JAKUBANY
Main Article Content
Abstract
External corrosion, which depends on environmental and operating conditions, is the main cause of structural deterioration of all metallic mains. Internal corrosion, on the other hand, can cause significant functional (hydraulic, water quality) deterioration within a distribution system. This work deals with the corrosion of water pipes which greatly affects the durability and failure rate of water systems. The test is evaluated in accordance with STN 75 7151 and ASTM D2688-11. The corrosion tests were carried out on raw and treated water at the water treatment plant in Jakubany.
Article Details
How to Cite
Galík, M., Kriš, J., & Ilavský, J. (2014). CORROSION TESTS AT THE WATER TREATMENT PLANT IN JAKUBANY. GeoScience Engineering, 60(4), 51–60. Retrieved from http://geoscience.cz/ojs/index.php/GSE/article/view/63
Issue
Section
Review Article